ELS Loading Control

ELS Loading Control
Central Loading Controls

All the benefits of a unified conveying system control can now reach every receiver, pump and valve in your operation with the all new ELS, Ethernet Loading System Control from Conair. This fully distributed control system utilizes reliable Allen-Bradley components, interconnected via industrial Ethernet to provide control of up to 500 receivers, 96 pumps and over 1000 source valves.
Simplified navigation using international icons on the large, touchscreen control panel will assure every authorized user is comfortable monitoring up to 90 independently operating conveying systems and making adjustments with little or no training.

  • Fully distributed Ethernet integration
  • 10-inch color touchscreen
  • Minimize wiring with modular components
  • Choose your level of control
  1. Downloads
  2. Videos
  3. Contact Us

Contact Us Form

Click here

email

info@conairgroup.com

Phone

+1 724 584 5500

Parts & Service

+1 800 458 1960 - United States

+1 814 437 6861 - International

parts@conairgroup.com

service@conairgroup.com

Features (click here to hide)

Industrial ethernet CAT 5 communications.

Allen-Bradley/Rockwell Automation components.

Choice of ArmorBlock or ArmorPoint I/O modules.

Up to six Human Machine Interface (HMI) panels.

Fully distributed, totally flexible, wiring and control.

Unloading (reverse regrind) system capability.

Ratio loading, positive discharge and fill sensor operation.

Purge and pocket valve operation.

MVP operation.

10-inch {254 mm} HMI standard, 15-inch {381 mm} optional.

Multiple levels of password protection.

International icon control navigation.

Specifications (click here to hide)
Model ELS
Performance Characteristics
Maximum number of vacuum receivers Up to 500
Maximum number of vacuum pumps 96 (any pump can be assigned as backup)
Maximum number of source valves 1000
Programmable Logic Controller (PLC)
Main control panel Allen-Bradley ControlLogix
Operator interface  Allen-Bradley PanelView Plus V.6
Screen size - diagnonal inches {mm} 10 {254} standard, 15 {381} optional
Output voltage to receivers/valves 24 VDC
Input voltage from to receivers 24 VDC
Output voltage to pumps 24 VDC
Power/amps 120 Vac/1 Phase 60 Hz (Optional 230 VAC)
Dimensions   inches {mm}
A - Height 20 {508}
B - Width 24 {610}
C - Depth 10 {254}
Weight - main enclosure   lb {kg}
Installed 60 {27.2}
Shipping 80 {36.3}
Maximum number of remote HMIs
Remote HMI panel 5 remote HMIs maximum
Input/output capabilities and maximum number of input/output devices
  

Main control panel

Block device

Point Device

Block pump Point pump

Block source

Point source Block alarm
Receivers - Up to 4 Up to 16 - - - - -
Pumps No inputs/outputs - - Up to 3 Up to 16 - - -
Valves - - - - Up to 8 Up to 32 -
Alarms - - - - - - - 1
Max. number blocks/points - 30 blocks 30 points 6 blocks 6 points 30 blocks 30 points 6 blocks
Total - 500 devices 96 pumps 1000 sources 6 alarms