RG Series Vacuum Pumps

RG Series Vacuum Pumps
Central Vacuum Pumps

For moderate distance conveying applications, nothing beats the simplicity of a regenerative vacuum pump from Conair. Replacing larger, more complex positive displacement pump/
motor units, RG Series Pumps utilize a one piece fan/motor unit to produce reliable vacuum power for loading systems up to 450 feet {137 m} and 7000 lbs/hr {3175 kg/hr}.
The simple, compact design allows the pump to be installed in nearly any indoor location, it can even be wall-mounted. Because the operating sound level is very low, concerns over
noise pollution and proximity to personnel are minimal.

  • Requires no maintenance
  • Quiet operation
  • Reliable components
  • Optional idle mode valve and timer
  • Optional filter canister
  1. Downloads
  2. Videos
  3. Contact Us

Specifications Sheet

 

Current Manual

English

Contact Us Form

Click here

email

info@conairgroup.com

Phone

+1 724 584 5500

Parts & Service

+1 800 458 1960 - United States

+1 814 437 6861 - International

parts@conairgroup.com

service@conairgroup.com

Options (click here to hide)

Optional idle mode valve and timer - This option eliminates frequent starting and stopping of the pump motor.

Optional filter canister - The filter canister provides simplified dust collection for virgin material systems.

Specifications (click here to hide)
 
     
   
Model RG1-3 RG1-6 RG1-11 RG2-5 RG2-8 RG2-16
Single Stage or Dual Stage Single Dual
  60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz
Motor  Hp  3.4 N/A  6.2  5.4  11.5  10.1  5.1 4.4 8.45 7.4  16.9  14.8 
Equivalent  kW {2.6}  N/A  {4.6}  {4.0}  {8.6}  {7.5}  {3.8}  {3.3}  {6.3}  {5.5}  {12.6}  {11.0} 
Line size   inches {mm} 1.5 {38.1}   N/A 2.0 {50.8}  1.5 {38.1}  2.5 {63.5}  2.0 {50.8}  1.5 {38.1}  1.5 {38.1}  2.0 {50.8}  1.5 {38.1}  2.5 {63.5}  2.0 {50.8} 
Airflow at material pickup  ft³/min 55  N/A  76  43 135 76  41 60 74 41 138 74 
Airflow at pump inlet  ft³/min 70 N/A 101 57 191 107 67 79 122 69 226 131
Pump pressure  inches Hg Vac. -6.2  N/A  -7.4  -7.4  -8.8  -8.4  -11.7  -7.3  -11.7  -12.2  -11.7  -12.9 
 Sound level (dba) 70   N/A  72  69  74  70  71  67  76  73  78  74 
 Inlet Orientation Back   Back   Back  Front   Back   Back  
 Outlet Orientation  Back  Back   Back   Back   Side   Back  
 Motor Type TEFC
 Dust collector recommended DC1 DC1 DC1 DC1 DC2 DC1 DC1 DC1 DC1 DC1 DC2 DC1
Dimensions   inches {mm}
 A- Height   14 {355.6} 16 {406.4}   21 {533.4}   25 {635.0}   17 {431.8}   23 {584.2}  
 B - Width   22 {558.8} 24 {609.6}   31 {787.4}   36 {914.4}   27 {685.8}   32 {812.8}  
 C - Depth   15 {381.0} 18 {457.2}   21 {533.4}   18 {457.2}   28 {711.2}   28 {711.2}  
Weight    lb {kg}
 Shipping   60 {27} 103 {47}   302 {137}   116 {53}   164 {74}   472 {214}  
 Installed   55 {25} 93 {42}   282 {128}   106 {48}   154 {70}   452 {205}  
 Voltage Full Load amps (FLA)             
 230V (220-275)/3 phase/ 60 Hz  10.3 N/A  16.4  N/A  30 N/A  14.2  N/A  23  N/A  50.2  N/A 
 460V (380-480)/3 phase/ 60 Hz  6 N/A  9.5  N/A   17.3 N/A  8.2  N/A  13.3  N/A  29  N/A 
 400V (345-415)/3 phase/ 50 Hz  N/A N/A  N/A  9.5  N/A  16.7  N/A  7.5  N/A  13.3  N/A  28 
 575V/3 phase/ 60 Hz  4.5 N/A  7.6  N/A  13.6  N/A  5.4  N/A  10.4  N/A  20.4  N/A 
 Motor type TEFC